Energised · 11 kV
London, UK · Power systems & EC&I engineering

Robust power systems, engineered for uncertainty.

We study, design, install, test and commission HV and LV networks for power plants, substations, waste-to-energy, oil & gas and process industries, from the first load-flow study to the day the system is energised.

10+years in the UK market
120relays through one FAT
1,200instrument loops documented
34services, study to support
TÜV Rheinland Functional SafetyCompEx Ex12IEC 61850 GOOSE / MMSIEC 61511 SILIEEE 1584 Arc FlashETAPSiemens PCS7ABB 800xAHAZOP · LOPA · DSEARSenior Authorised Person (HV)CDM 2015FAT / SAT TÜV Rheinland Functional SafetyCompEx Ex12IEC 61850 GOOSE / MMSIEC 61511 SILIEEE 1584 Arc FlashETAPSiemens PCS7ABB 800xAHAZOP · LOPA · DSEARSenior Authorised Person (HV)CDM 2015FAT / SAT
UK registered companyHoweizeh Limited, England & Wales, Company No. 10014102, since 2016
TÜV Rheinland FS EngineersCertified functional safety engineers for SIS / SIL work to IEC 61511
Senior Authorised PersonHV switching and safety documents on your site
CompEx Ex12Design of equipment for hazardous areas under DSEAR
Chartered & IETCEng-led team, members of the Institution of Engineering and Technology
Sheet 01 · How we work

One team, from the first study to the first switch-on.

A real project, from the first study to the day the plant goes live, filmed from our own sites and drawings. Tap a stage to jump to it, or turn on the narration.

ENERGISED ✓
H-INFINITY
Robust power systems, engineered for uncertainty.

Sheet 02 · Interactive

Walk the site in 3D.

The same project as a live 3D model: study, design, install, test and energise. Drag to look around, or tap a stage.

01 · STUDY
ENERGISED ✓
Transformer being lifted onto its plinth
⟲ Drag to look around

Sheet 03 · Services

Six disciplines, one accountable team.

Take a single study or the whole package. The engineers who model your network specify the equipment, witness the factory tests and energise it on site.

01

Power & Electrical Studies

  • Power flow study
  • Short circuit study
  • Arc flash study (IEEE 1584)
  • Harmonic analysis
  • Protection & grading study
02

Power & Electrical Design

  • Concept & planning design
  • Detailed primary & secondary design
  • Power management system (PMS)
  • Equipment specification
  • Cable sizing & schedules
03

Power & Electrical Consultancy

  • General consultancy
  • Technical specifications
  • Single line diagrams
  • Financial analysis
  • Technical analysis
04

Control & Instrumentation

  • SIS design & implementation
  • HAZOP & LOPA studies
  • CompEx hazardous-area equipment
  • Commissioning services
05Flagship

Transformer Services

  • Transformer design
  • On-site oil services
  • Handling & assembly
  • Test & commissioning
  • Routine maintenance
06

Testing & Maintenance

  • HV testing: cables, switchgear, earthing
  • Relay testing & secondary injection
  • FAT / SAT witnessing
  • Routine maintenance & testing
Sheet 04 · Free site check

Is your electrical system safe and compliant?

Six questions, two minutes. You get an indicative risk rating and the studies most likely to matter for your site.

1. When was your last protection and coordination study?
2. Do you have a current arc flash assessment, with labels on the switchgear?
3. Has the network changed since that study (solar, batteries, CHP, big new loads)?
4. When were your protection relays last tested by secondary injection?
5. How old is your main HV or LV switchgear?
6. Are you adding generation or storage that needs a G99 connection?
“We aim to give customers the highest quality system: a complete package from design, supply and commissioning.”
Dr Emad Hamadi PhD · Technical Director
Sheet 05 · Selected projects

Energised, tested, handed over.

Biomass, waste-to-energy, industrial upgrades and international substations, delivered as complete packages since 2017.

New switchgear during commissioning at Ellesmere Port
2022–23
Ellesmere PortRecresco

Power plant upgrade

Complete power system upgrade from design to commissioning: power studies, equipment supply and installation, DNO outage coordination and full energisation, including renewables integration.

Power studySupply & installDNO outageEnergisation
Crane lifting the new transformer into place in Boston
2021
Boston, UKIndustrial Power & Marine

Boston Biomass No.2 power plant

Electrical network upgrade for the refuse-derived fuel (RDF) system: 11 kV switchgear, an 11 kV/433 V transformer, LV and DC battery panels, HV/LV cabling and a GRP enclosure, through FAT, SAT and operator training.

11 kV / 433 VLoad flowProtection studyFAT / SAT
Engineer on site at the Hull biomass plant
2020
Hull, UKIndustrial Power & Marine

Hull Biomass No.1 power plant

Power study for the RDF upgrade, then supply, installation and commissioning of 11 kV switchgear, an 11/0.433 kV transformer, LV and DC battery panels, cable tray and a GRP enclosure, with the DNO outage planned around the plant.

CT calculationCable sizingSupply & installTraining
HV cable terminations inside new switchgear
2019
LondonABB · for London Energy

Edmonton EfW switchgear replacement

Network study in every scenario, CT saturation modelled to IEC 61869 with the generators' DC component, a reverse-blocking directional protection scheme over IEC 61850 GOOSE, a plant trip matrix and arc flash to IEEE 1584 / NFPA 70E.

ETAPIEC 61850Arc flashTrip matrix
Waste-to-energy plant stacks
2018
LondonElektrobudowa

Edmonton EfW automation package

GOOSE/MMS and Modbus signal lists, SAS architecture, CID files for every relay, and a multipoint synchronising panel running Howeizeh's own NG-100 power management system, plus UPS DC design with SAFT battery sizing.

GOOSE / MMSNG-100 PMSSynchronisingCDM
Relay test bench during factory acceptance testing
2018
SkelmersdaleVoltech & Siemens

Qatar transmission expansion, Phase 13

As Siemens' UK representative: factory acceptance testing of 11 kV HV panels with 120 protection relays, relay configuration, secondary injection and signed test reports.

120 relaysFATSecondary injection
Engineers at an LV panel during commissioning
2017
Milton KeynesAmey

Milton Keynes waste-to-energy plant

Protection and discrimination study, design validation from the DNO substation to every consumer, HV/LV commissioning before first energisation, more than 10 design changes during commissioning, loop diagrams for 1,200 loops and annual SIS proof testing.

1,200 loopsSATRoot cause analysisSIS proof test
Sheet 06 · On site

Hard hats on, hands on.

Our engineers terminate the cables, run the injection tests and stand beside the switchgear when it closes for the first time.

Transformer lift onto its plinth
Thermal imaging of a control panel
HV cable termination
Site team at a substation
Test instruments on a live job
Pulling HV cable
Insulation resistance testing
Earthing and cable route works
Sheet 07 · Leadership

Engineers who sign the drawings and stand on site.

Internationally qualified, with decades of hands-on delivery across power, oil & gas and process industries.

Dr Emad Hamadi

Dr Emad Hamadi

PhD · MSc · BEng · MIET · AFHEA · MInstLM · FS Eng (TÜV)
Technical Director, Power

Electrical engineer across oil & gas, thermal power and renewables. Senior Authorised Person for HV switching, TÜV Rheinland Functional Safety Engineer (#17340/18) and CompEx Ex12 certified for hazardous-area design.

SLD & protectionLoad flow / short circuitHV commissioningCT/VT sizingEarthing
Dhiraj Kumar

Dhiraj Kumar

CEng · BEng · FS Eng (TÜV Rheinland)
EC&I Manager, Control & Instrumentation

16+ years on waste-to-energy, oil & gas, petrochemical and non-ferrous metals projects, with Emerson, Honeywell, Siemens and ABB control systems.

PCS7 / DeltaVABB 800xAAllen-BradleyIEC 61511Six Sigma
Sheet 08 · Partners & clients

Trusted by the names behind the plant.

From global OEMs to the operators who keep Britain's waste-to-energy and biomass plants running.

Partner logos: INTPRO, Industrial Power & Marine, ABB, 4 Power Engineering, CPA Solutions, MANES, OM Switchgear & Protection, Amey, PCML Midlands, Siemens
EPESAbbottThalia Waste ManagementMagnus
Sheet 09 · Contact

Start with a free consultation.

Initial consultation, site survey and gap analysis at no cost, before any contract is signed.

Registered office

20–22 Wenlock Road, London N1 7GU, UK